Stop bit.
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
|
_SRP_BIT_STOP_1_0 |
1 stop bit |
_SRP_BIT_STOP_1_5 |
1.5 stop bit |
_SRP_BIT_STOP_2 |
2 stop bit |
Conditions for use |
Read and write methods may fail to function as the result of a poorly configured stop bit. |
Default value |
_SRP_BIT_STOP_1_0 |
Flow control (true or false).
Adelia type |
BOOL. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
None |
Conditions for use |
The port opening method may fail to function as the result of a poorly configured flow control. |
Default value |
*FALSE |
Static name of the object.
Adelia type |
ALPHA(128). |
Accessibility |
|
Layout design mode |
Read/Write. |
Execution mode |
Read. |
Associated constants |
None |
Conditions of use |
None |
Default value |
Prefix of the basic object. |
Parity bit.
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
|
_SRP_NO_PARITY |
No parity bit |
_SRP_EVEN_PARITY |
Even parity |
_SRP_ODD_PARITY |
Odd parity |
_SRP_MARKED_PARITY |
Marked parity |
Conditions for use |
Read and write methods may fail to function as the result of a poorly configured parity bit. |
Default value |
_SRP_NO_PARITY |
Port number selected by the serial port object.
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
|
_SRP_SERIAL_PORT_1 |
"COM1:" serial port |
_SRP_SERIAL_PORT_2 |
"COM2:" serial port |
_SRP_SERIAL_PORT_3 |
"COM3:" serial port |
_SRP_SERIAL_PORT_4 |
"COM4:" serial port |
Conditions for use |
The selected port must be connected so that the serial port object functions correctly. With ports whose number is higher than 4, specify the port number directly. |
Default value |
_SRP_SERIAL_PORT_1. |
Transfer rate of the selected port in bauds per second (words per second).
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants | |
_SRP_RATE_110 |
110 baud rate |
_SRP_RATE_300 |
300 baud rate |
_SRP_RATE_600 |
600 baud rate |
_SRP_RATE_1200 |
1200 baud rate |
_SRP_RATE_2400 |
2400 baud rate |
_SRP_RATE_4800 |
4800 baud rate |
_SRP_RATE_9600 |
9600 baud rate |
_SRP_RATE_14400 |
14400 baud rate |
_SRP_RATE_19200 |
19200 baud rate |
_SRP_RATE_38400 |
38400 baud rate |
_SRP_RATE_56000 |
56000 baud rate |
_SRP_RATE_128000 |
128000 baud rate |
_SRP_RATE_256000 |
256000 baud rate |
Conditions for use |
You should choose the rate carefully, in order to read and write coherent data. |
Default value |
_SRP_RATE_110 |
Size (in bits) of each data word sent or received.
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
|
_SRP_SIZE_5 |
5 bits per word |
_SRP_SIZE_6 |
6 bits per word |
_SRP_SIZE_7 |
7 bits per word |
_SRP_SIZE_8 |
8 bits per word |
Conditions for use |
You should choose the data format carefully, in order to read and write coherent data. |
Default value |
_SRP_SIZE_5 |
Value of the object's X-axis, relative to the area covered by the window.
The reference point (origin) is the top left corner of the object.
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
None |
Conditions for use |
None |
Default value |
None |
Value of the object's Y-axis, relative to the area covered by the window.
The reference point (origin) is the top left corner of the object.
Adelia type |
NUM_BIN_4. |
Accessibility |
|
Layout design mode |
Read / Write. |
Execution mode |
Read / Write. |
Associated constants |
None |
Conditions for use |
None |
Default value |
None |