Syntax

RECEIVE SeriesVarId


SeriesVarId

SeriesVarId VarId | None


Description

This instruction gives the list of parameters SeriesVarId external to the program. With the RECEIVE instruction, the parameters are received by the called program and automatically sent back to the calling program when the end of the called program is reached.


It can be placed anywhere, but for reasons of readability, it is suggested that the instruction be placed at the beginning of the program.


Only one RECEIVE instruction per program is permitted.


Association of the parameters between the calling program and the called program is done by their position in the CALL and RECEIVE instructions.


Important note: The variables set as parameters cannot be data structure (DS) subfields.


Example

* 3 parameters are exchanged:

the name


the customer code


and a return code


* (PROGRAM ORDER_ENTRY)

*

CALL CUST_WINDOW W_CUST_NAME W_CUST_CODE W_RETURN_CODE

*

IF     W_RETURN_CODE <> 'N'

ZZ_CUST_CODE = W_CUST_CODE

ZZ_CUST_NAME = W_CUST_NAME

END


* (PROGRAM CUST_WINDOW)

RECEIVE R_NAME R_CUSTOMER_CODE R_RETURN_CODE

R_RETURN_CODE = *BLANK

PROCESS 01

TRANSACTION 01

IF     *F03

R_RETURN_CODE = 'N'

TERMINATE

END

* ...


Other example:


* Let's assume that you have a program variable PW_RET_COD

* declaration of a memory list at the beginning of the program

DECL LIST PW_LST_MEMO EM_EMPL_NAME EM_EMPL_FIRST_NAME EM_EMPL_CODE EM_EMPL_CITY

* declare the memory list and return code as parameters

RECEIVE  PW_LST_MEMO  PW_COD_RET


See also the list of 4GL instructions by topic

↑ Top of page