Stop bit.

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

 

_SRP_BIT_STOP_1_0

1 stop bit

_SRP_BIT_STOP_1_5

1.5 stop bit

_SRP_BIT_STOP_2

2 stop bit

Conditions for use

Read and write methods may fail to function as the result of a poorly configured stop bit.

Default value

_SRP_BIT_STOP_1_0

 

 

Flow control (true or false).

Adelia type

BOOL.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

None

Conditions for use

The port opening method may fail to function as the result of a poorly configured flow control.

Default value

*FALSE

 

 

Static name of the object.

Adelia type

ALPHA(128).

Accessibility

 

Layout design mode

Read/Write.

Execution mode

Read.

Associated constants

None

Conditions of use

None

Default value

Prefix of the basic object.

 

 

Parity bit.

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

 

_SRP_NO_PARITY

No parity bit

_SRP_EVEN_PARITY

Even parity

_SRP_ODD_PARITY

Odd parity

_SRP_MARKED_PARITY

Marked parity

Conditions for use

Read and write methods may fail to function as the result of a poorly configured parity bit.

Default value

_SRP_NO_PARITY

 

 

Port number selected by the serial port object.

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

 

_SRP_SERIAL_PORT_1

"COM1:" serial port

_SRP_SERIAL_PORT_2

"COM2:" serial port

_SRP_SERIAL_PORT_3

"COM3:" serial port

_SRP_SERIAL_PORT_4

"COM4:" serial port

Conditions for use

The selected port must be connected so that the serial port object functions correctly.

With ports whose number is higher than 4, specify the port number directly.

Default value

_SRP_SERIAL_PORT_1.

 

 

Transfer rate of the selected port in bauds per second (words per second).

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants  

_SRP_RATE_110

110 baud rate

_SRP_RATE_300

300 baud rate

_SRP_RATE_600

600 baud rate

_SRP_RATE_1200

1200 baud rate

_SRP_RATE_2400

2400 baud rate

_SRP_RATE_4800

4800 baud rate

_SRP_RATE_9600

9600 baud rate

_SRP_RATE_14400

14400 baud rate

_SRP_RATE_19200

19200 baud rate

_SRP_RATE_38400

38400 baud rate

_SRP_RATE_56000

56000 baud rate

_SRP_RATE_128000

128000 baud rate

_SRP_RATE_256000

256000 baud rate

Conditions for use

You should choose the rate carefully, in order to read and write coherent data.

Default value

_SRP_RATE_110

 

 

Size (in bits) of each data word sent or received.

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

 

_SRP_SIZE_5

5 bits per word

_SRP_SIZE_6

6 bits per word

_SRP_SIZE_7

7 bits per word

_SRP_SIZE_8

8 bits per word

Conditions for use

You should choose the data format carefully, in order to read and write coherent data.

Default value

_SRP_SIZE_5

 

 

Value of the object's X-axis, relative to the area covered by the window.

The reference point (origin) is the top left corner of the object.

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

None

Conditions for use

None

Default value

None

 

 

Value of the object's Y-axis, relative to the area covered by the window.

The reference point (origin) is the top left corner of the object.

Adelia type

NUM_BIN_4.

Accessibility

 

Layout design mode

Read / Write.

Execution mode

Read / Write.

Associated constants

None

Conditions for use

None

Default value

None

 

 

 

 

↑ Top of page