Products Downloads


French version


 

Access

To open this page, click the Verification tab in the Editor Options dialog box.


You can use this tab to change the options relating to the 4GL source code dynamic analysis feature.

This feature provides input to the object inspector and reports any syntax errors in real time.


Source analysis

Check boxes

Analyze source during input

Checked

The 4GL source is automatically analyzed after every change.

Unchecked

Data is not verified as it is input.

Default: checked.


Enable Object Inspector only

Only the Object Inspector's features are activated.

Default: disabled.


Show syntax errors and warnings

Errors are underlined in the 4GL source, and solutions may be suggested.

Default: enabled.


Disable analysis in documents in read-only mode

Read-only documents will not be analyzed.

Default: disabled.


Latency time

Sets the delay (in ms) before the dynamic source code verification is performed automatically.


Data environment maintenance
Maintain the environment continuously

Checked

Whenever a verification is triggered, the data environment is analyzed and where applicable, a complete check of the source performed.

This can create performance problems when analyzing large programs if the database is slow to respond (in case of remote access, for example), or if the development workstation is not particularly powerful.

Default: checked.


Analyze the management rule source

Checked

The management rules are partially analyzed to supplement the data environment.

For performance reasons, only rules included using an INSERT_MR instruction are processed, and the parameters are not substituted (rules are only processed once).

Default: checked.


Message filtering

Data input

Message filtering

The combo box lets you specify the level of messages returned by the verification operation:

Show all messages

Displays all messages (i.e. information, error and warning messages).

Show errors and warnings

Hides any information messages.

Show errors only

Hides any information and warning messages.


Buttons

OK

Validates any changes and closes the dialog box.


Cancel

Closes the dialog box without validating any changes.

Keyboard shortcut: Esc.